Industrial Filter Bags · Filter Cartridges · Filter Housings · Filter Mesh Manufacturer & Custom Supplier Replacement style · OEM size · Custom micron rating · Industrial filtration supply
Fine filtration and validation

0.22 Micron Pleated Filter Cartridge

Separate particle ratings from sterile claims. Compare material families, documented retention and operating requirements.

Request a configuration review
PP pleated filter cartridge — representative family image
PP family image for illustration. The image does not identify an independently verified 0.22 µm SKU; confirm the ordered construction.
Selection summary

A 0.22 micron pleated filter cartridge is a fine filtration grade that must be specified together with membrane material, retention evidence and service conditions. A cartridge carrying a 0.22 µm rating is not automatically a validated sterilizing-grade filter.

When to evaluate 0.22 µm filtration

Separate particle ratings from sterile claims

For a water or process-liquid polishing stage, compare PP, PTFE or PVDF families that list this exact rating. Where the application requires microbial control, ask for the specific product validation and the operating conditions covered by that validation before selecting a cartridge.

Check the complete filtration train

If an existing specification calls for 0.2 µm PES or nylon, do not silently substitute 0.22 µm. The detailed PES and nylon catalog pages list 0.2 µm; confirm whether a qualified 0.22 µm version exists or whether the process can accept the documented alternative.

Material options and exact-grade availability

This is a cross-material selection guide. The linked family pages are the catalog references, not substitutes for a confirmed grade-specific data sheet. Listed family information does not establish that every combination of dimensions, seals and rating is available.

Material / requestCatalog statusSelection question
PPExact 0.22 µm grade listed on the detailed family pagePolypropylene; evaluate for compatible water and process liquids.
PTFEExact 0.22 µm grade listed on the detailed family pageConfirm hydrophilic or hydrophobic configuration and complete fluid compatibility.
PVDFExact 0.22 µm grade listed on the detailed family pagePolyvinylidene fluoride membrane; confirm the selected grade and operating envelope.

For the existing polypropylene-specific product guide, see 0.22 micron PP pleated filter cartridge. That page addresses the PP construction; this page compares material and process-selection choices.

Catalog precision: the detailed PES and nylon pages list 0.2 µm. Do not treat 0.2 and 0.22 µm as a confirmed interchangeable product specification.

0.22 versus 0.45 micron

0.22 µm states a finer grade than 0.45 µm, but a pore-size comparison is not a microbial validation. Select a final filter against the process acceptance criteria and qualified product data, not a generalized sterile-filter claim.

Nearby selection guides: 0.1 µm · 0.45 µm. Compare equivalent efficiency definitions and cartridge dimensions before changing grade.

Specify the cartridge before ordering

Required rating0.22 µm; state nominal/absolute definition and required retention efficiency.
AvailabilityListed material families above; confirm the exact orderable combination.
Dimensions and interfaceConfirm actual length, OD, ID, end-cap drawing and gasket arrangement against the existing housing.
Fluid and hydraulicsProvide fluid composition, concentration, viscosity at temperature, flow and allowable clean differential pressure.
Operating limitsObtain configuration-specific temperature, pressure and change-out limits. Limits cannot be inferred from the micron number.
DocumentsRequest a grade-specific data sheet, retention method and any product-contact or validation records required for the application.

Trial and acceptance plan for 0.22 µm

Ask whether retention data is particulate or microbial, which challenge method was used and which temperature, pressure, fluid and exposure limits apply. If the process needs integrity testing, obtain the product-specific method and acceptance criteria.

  1. Define the required downstream particle or process-quality result before the trial.
  2. Install the confirmed cartridge and seals; check for bypass and record clean differential pressure at the design flow.
  3. Track throughput, particle results and differential-pressure growth under representative feed conditions.
  4. Approve a change-out criterion below the cartridge and housing limits. Replace earlier if process quality or flow requires it.

No grade-specific flow rate, retention percentage, service life, certification or microbial-validation result is asserted by this guide. Those values must come from documentation for the ordered configuration.

Questions about 0.22 micron pleated cartridges

What does a 0.22 micron pleated filter cartridge mean?

A 0.22 micron pleated filter cartridge is a fine filtration grade that must be specified together with membrane material, retention evidence and service conditions. A cartridge carrying a 0.22 µm rating is not automatically a validated sterilizing-grade filter.

0.22 versus 0.45 micron: which should I choose?

0.22 µm states a finer grade than 0.45 µm, but a pore-size comparison is not a microbial validation. Select a final filter against the process acceptance criteria and qualified product data, not a generalized sterile-filter claim.

Is the 0.22 micron rating nominal or absolute?

The number alone does not say. Request the retention efficiency, challenge conditions and test method for the exact grade. Do not assume a universal efficiency percentage from the word nominal or absolute.

Will this cartridge fit my existing housing?

Match the actual overall length, outside and inside diameters, end-cap interface and seal arrangement against the housing drawing. A matching micron rating or nominal length does not establish fit.

Does this rating prove sterile filtration or dissolved-contaminant removal?

No. Particle-rating information alone does not establish sterilizing performance or removal of dissolved salts and chemicals. Microbial claims need product-specific evidence and process validation; dissolved contaminants require an appropriate treatment process.

How do I request a quotation?

Send the required rating and efficiency, liquid and concentration, flow, viscosity, temperature, pressure, particle load, cartridge dimensions, end-cap drawing, seals, quantity and required documentation. Ask INCE filtration to confirm the exact configuration before purchase.

Catalog references and related ratings

Prepared by INCE filtration from the linked material-family catalog information. Reviewed: 30 October 2026. Availability statements describe the published family lists at preparation time; a written quotation and data sheet establish the supplied configuration.

PP family · PTFE family · PVDF family

All pleated filter cartridges · Request a configuration review

Filtration Engineer
● Online
×
WhatsApp