Industrial Filter Bags · Filter Cartridges · Filter Housings · Filter Mesh Manufacturer & Custom Supplier Replacement style · OEM size · Custom micron rating · Industrial filtration supply
Coarsest listed glass fiber grade

100 Micron Pleated Filter Cartridge

Define what the coarse stage must protect. Compare material families, documented retention and operating requirements.

Request a configuration review
Glass Fiber pleated filter cartridge — representative family image
Glass Fiber family image for illustration. The image does not identify an independently verified 100 µm SKU; confirm the ordered construction.
Selection summary

A 100 micron pleated filter cartridge is the coarsest grade listed on the detailed INCE glass fiber series page. It is a candidate for coarse suspended-particle prefiltration where its documented retention meets the downstream protection requirement.

When to evaluate 100 µm filtration

Define what the coarse stage must protect

Before selecting this grade for equipment protection, establish the equipment supplier’s particle tolerance. A 100 µm filter is not a substitute for a finer cartridge when the damaging particles fall below its demonstrated retention range.

Check the complete filtration train

If the feed contains a heavy coarse-solids load, evaluate whether upstream screening or separation is appropriate before the cartridge stage. Choose the complete treatment train using maintainability and verified quality, not only a desired nominal flow.

Material options and exact-grade availability

This is a cross-material selection guide. The linked family pages are the catalog references, not substitutes for a confirmed grade-specific data sheet. Listed family information does not establish that every combination of dimensions, seals and rating is available.

Material / requestCatalog statusSelection question
Glass FiberExact 100 µm grade listed on the detailed family pageConfirm the multilayer media, support construction and approved operating conditions.

100 versus 70 micron

70 µm is the finer stated grade within the same listed family. Use 100 µm only where its verified retention is sufficient; evaluate 70 µm or a finer stage when the protection requirement calls for it.

Nearby selection guides: 70 µm. Compare equivalent efficiency definitions and cartridge dimensions before changing grade.

Specify the cartridge before ordering

Required rating100 µm; state nominal/absolute definition and required retention efficiency.
AvailabilityListed material families above; confirm the exact orderable combination.
Dimensions and interfaceConfirm actual length, OD, ID, end-cap drawing and gasket arrangement against the existing housing.
Fluid and hydraulicsProvide fluid composition, concentration, viscosity at temperature, flow and allowable clean differential pressure.
Operating limitsObtain configuration-specific temperature, pressure and change-out limits. Limits cannot be inferred from the micron number.
DocumentsRequest a grade-specific data sheet, retention method and any product-contact or validation records required for the application.

Trial and acceptance plan for 100 µm

Specify the coarse-particle target and downstream quality limit. Confirm the supporting structure, seal materials, housing fit and approved differential-pressure limit, then validate the proposed change-out procedure under operating conditions.

  1. Define the required downstream particle or process-quality result before the trial.
  2. Install the confirmed cartridge and seals; check for bypass and record clean differential pressure at the design flow.
  3. Track throughput, particle results and differential-pressure growth under representative feed conditions.
  4. Approve a change-out criterion below the cartridge and housing limits. Replace earlier if process quality or flow requires it.

No grade-specific flow rate, retention percentage, service life, certification or microbial-validation result is asserted by this guide. Those values must come from documentation for the ordered configuration.

Questions about 100 micron pleated cartridges

What does a 100 micron pleated filter cartridge mean?

A 100 micron pleated filter cartridge is the coarsest grade listed on the detailed INCE glass fiber series page. It is a candidate for coarse suspended-particle prefiltration where its documented retention meets the downstream protection requirement.

100 versus 70 micron: which should I choose?

70 µm is the finer stated grade within the same listed family. Use 100 µm only where its verified retention is sufficient; evaluate 70 µm or a finer stage when the protection requirement calls for it.

Is the 100 micron rating nominal or absolute?

The number alone does not say. Request the retention efficiency, challenge conditions and test method for the exact grade. Do not assume a universal efficiency percentage from the word nominal or absolute.

Will this cartridge fit my existing housing?

Match the actual overall length, outside and inside diameters, end-cap interface and seal arrangement against the housing drawing. A matching micron rating or nominal length does not establish fit.

Does this rating prove sterile filtration or dissolved-contaminant removal?

No. Particle-rating information alone does not establish sterilizing performance or removal of dissolved salts and chemicals. Microbial claims need product-specific evidence and process validation; dissolved contaminants require an appropriate treatment process.

How do I request a quotation?

Send the required rating and efficiency, liquid and concentration, flow, viscosity, temperature, pressure, particle load, cartridge dimensions, end-cap drawing, seals, quantity and required documentation. Ask INCE filtration to confirm the exact configuration before purchase.

Catalog references and related ratings

Prepared by INCE filtration from the linked material-family catalog information. Reviewed: 30 October 2026. Availability statements describe the published family lists at preparation time; a written quotation and data sheet establish the supplied configuration.

Glass Fiber family

All pleated filter cartridges · Request a configuration review

Filtration Engineer
● Online
×
WhatsApp