Direct answer: if the filter bag part number is unknown, do not order from length and micron rating alone. Send a clean used sample when possible, plus the housing model, basket dimensions, flat and finished bag measurements, ring/collar geometry, seam construction, media identification, operating conditions and photos with a scale. A supplier can then propose a controlled first article rather than guess a “standard” replacement.
Have a replacement bag but no part number?
Send housing make/model, basket inside diameter and depth, bag flat width and length, collar/ring photos and measurements, seam type, media if known, micron target, liquid, temperature, flow, quantity and destination. If safe and permitted, offer a clean sample for confirmation.

Which measurements are essential when the part number is missing?
| Measurement | How to record it | Failure prevented |
|---|---|---|
| Bag flat width and finished diameter | Photograph a relaxed bag beside a ruler; state whether value is flat or circumferential | Wrinkling, poor basket support or wrong capacity |
| Finished length | Measure from sealing reference to closed end; exclude handles unless noted | Bag bottoming or excessive unsupported length |
| Ring/collar section | Outside/inside diameter, thickness, profile, material and orientation | Bypass or inability to seat the cover |
| Basket dimensions | Inside diameter, usable depth, top support geometry and perforation | Unsupported media, abrasion and collapse |
| Seam and bottom | Sewn or welded, seam position, thread, bottom shape and any reinforcement | Leak paths and premature failure |

Why “Size 1” or “Size 2” is not enough
Common industry labels are useful screening terms, but manufacturers can differ in ring profile, finished dimensions and tolerance. Eaton public product pages, for example, identify a specific Size 01 bag as 7 × 17 inches (180 × 430 mm) and Size 02 as 7 × 32 inches (180 × 810 mm), together with the media, micron value and ring type. A replacement RFQ should be at least that specific and should still verify the existing housing. See an Eaton Size 02 product example.
Do not copy competitor proprietary part numbers as if they were universal standards. Use the existing part number as a cross-reference, then provide dimensions and operating duty so the proposed replacement can be checked independently.
Convert the existing bag into an approval drawing
INCE can review your measurement sheet, photos and clean sample and return a proposed construction for first-article approval. Mark every critical dimension and identify any value that is approximate.
How should a used sample be handled?
- Confirm the sample can be legally and safely shipped.
- Clean, dry and label it; disclose the previous process chemical and any residue risk.
- Do not send a contaminated hazardous sample without written carrier and recipient approval.
- Protect the collar from deformation and avoid folding the ring.
- Include a photo set before shipping in case transit changes the shape.
If a physical sample cannot be shipped, provide close-up photographs on a neutral background with a steel rule or caliper visible. Photograph the ring profile from the top and side, the seam, bottom, label and the bag installed in the basket. Include a simple sketch identifying finished rather than flat dimensions.

What operating information prevents the wrong media choice?
Send the liquid composition, pH where meaningful, maximum temperature, normal and peak flow, clean and terminal differential pressure, particle description, solids loading, batch or continuous operation, required micron efficiency, cleaning exposure and whether fiber release is critical. If the original media is unknown, label it “unknown” rather than guessing from color or feel.
Review the industrial filter bag range, PP filter bags and nylon mesh filter bags. The goal of the article is to create a separate replacement-identification path, not compete with those commercial category pages.
Frequently asked questions
Can a supplier identify a filter bag from photos only?
Photos can narrow the options, but critical fit still requires dimensions, housing/basket data and preferably a clean sample or an approved first article.
Should I measure the old bag after use?
Yes, but state that it is a used measurement because heat, chemicals and loading can stretch or shrink media. Housing and basket dimensions provide an independent reference.
What if the media and micron rating are unknown?
Describe the liquid, captured particles, downstream requirement and current performance. A supplier may propose a trial, but should not invent the original rating.
Get replacement filter bag pricing
Send housing, basket, bag and ring dimensions; media/micron if known; liquid, temperature, flow, quantity, destination and photos or a clean sample. INCE will quote only after the compatibility gaps are identified.