Industrial Filter Bags · Filter Cartridges · Filter Housings · Filter Mesh Manufacturer & Custom Supplier Replacement style · OEM size · Custom micron rating · Industrial filtration supply

How Do Buyers Cross-Reference a Pall-Style High-Flow Filter Cartridge?

A procurement checklist for cross-referencing a Pall-style high-flow replacement cartridge using model, dimensions, end caps, seals, media and operating duty.

Pall-style high flow replacement filter cartridges for sample qualification

Direct answer: To cross-reference a Pall-style high-flow filter cartridge, record the installed length, outside and inside diameters, end-cap geometry, seal material, micron rating and service conditions. INCE publishes replacement-style cartridges with 20, 40 and 60 inch lengths, a 156 mm outside diameter and 73.5 mm inside diameter as reference values; the original model, photos and measured interface still control compatibility. See the Pall-style high-flow replacement cartridge page. Pall is a third-party trademark; INCE products are compatible replacement-style products, not original Pall products and not represented as endorsed by Pall.

Need a Cross-Reference Review?

Send the original model code, overall length, OD and ID, both end-cap photos and dimensions, gasket material, micron rating, liquid, flow, temperature, quantity and destination. Do not remove an installed cartridge solely on the basis of a web dimension.

Request a Compatibility Quote

Pall-style high flow replacement filter cartridges for sample qualification
INCE replacement-style high-flow cartridges. Final compatibility requires model and dimensional review; these are not represented as original Pall products.

Which Dimensions Identify a Pall-Style High-Flow Cartridge?

Identification field INCE published reference What the buyer should verify
Length 20, 40 or 60 inch; custom length subject to review Measure the installed element and identify the nominal housing length
Outside diameter 156 mm Measure the largest body diameter and any interface features
Inside diameter 73.5 mm Measure the open-bore and mating-interface diameter
End configuration Replacement-style geometry varies by installed design Send clear photos and dimensions of both ends
Seal Silicone, EPDM, NBR or FKM options are published Confirm material, profile, size and chemical compatibility
Micron rating 1, 2, 3, 5, 10, 20, 40, 50, 70 or 100 µm published options State the required rating and whether an existing specification defines efficiency

A model-code match is helpful but not sufficient when an old label is incomplete, a housing has been modified or a local replacement has already been installed. Use the original documentation plus direct measurements. If the end cap, seal groove or flow direction differs, stop the substitution review until the interface is confirmed.

High flow replacement cartridge end and body configuration
Use end-cap and body photographs together with measured dimensions; a visual resemblance alone is not a fit guarantee.

What Media and Operating Data Must Be Compared?

INCE publishes polypropylene and glass-fiber media options with hot-melt welding and no adhesive in the element construction. Published reference limits include a maximum temperature of 82 °C for a polypropylene configuration and 121 °C for a glass-fiber configuration. Published differential-pressure references include 5.2 bar at 20 °C and 3.4 bar at 121 °C for the stated glass-fiber configuration, with a recommended change-out differential pressure of 2.4 bar. These figures are not universal permissions for every cartridge, seal, housing or chemical.

  • Liquid name, concentration, viscosity, solids loading and any oxidizer or solvent exposure.
  • Normal and maximum operating temperature and pressure.
  • Required flow per element and the number of elements in the housing.
  • Micron rating, filtration-efficiency requirement and downstream cleanliness objective.
  • Current clean differential pressure, change-out criterion and observed failure mode.
  • Media, support/core material and gasket material required by the approved process specification.

Why a Sample Qualification Is Safer Than Ordering by Brand Name Alone

For a first replacement, compare the sample against the installed element and the approved housing drawing. Check overall length, sealing engagement, end-cap orientation, bore and support contact. A plant should then apply its own installation, flushing, integrity and process-acceptance procedures before full production use. INCE does not claim that a compatible-style element is the original branded cartridge.

Pall style high flow filter cartridge replacement for industrial filtration
Replacement-style high-flow element for industrial filtration. Confirm flow direction, end interface, seal and process duty before purchase.

RFQ Checklist for a Comparable Replacement Quote

RFQ item Minimum information
Identity Original manufacturer and complete model code; photo of the label
Dimensions Overall length, OD, ID, both end-cap dimensions and seal-groove details
Materials Filter media, core/support material and gasket material
Duty Liquid, concentration, viscosity, solids, temperature, pressure and target flow
Filtration Micron/efficiency requirement and change-out differential pressure
Commercial Quantity, trial quantity, destination, packaging and document needs

Avoid an Unverified Drop-In Claim

Attach the installed cartridge photos and a dimensioned sketch. INCE can identify open points, propose a replacement-style configuration and state which dimensions still require sample approval.

Send Your Specification

Frequently Asked Questions

Are INCE Pall-style cartridges original Pall cartridges?

No. They are compatible replacement-style products. Pall is a third-party trademark, and the products should not be described as original or Pall-endorsed.

Can I cross-reference a cartridge from the model number alone?

Do not rely on the model alone. Confirm length, OD, ID, end-cap geometry, seal, media, micron rating, flow direction and service conditions.

What dimensions does INCE publish for this replacement style?

INCE publishes 20, 40 and 60 inch lengths, 156 mm outside diameter and 73.5 mm inside diameter as reference values, subject to final model and interface confirmation.

Request Replacement-Style Pricing

Send the model, measurements, photos, seal and media requirements, micron rating, service data, quantity and destination so the quotation can define the offered configuration.

Get OEM Pricing

Related Articles

Continue Reading About Liquid Filtration

Need a Filter Bag Recommendation?

Send the liquid, micron target, flow, pressure, temperature, bag dimensions and quantity for review.

Start a Filter Bag Inquiry
Filtration Engineer
● Online
×
WhatsApp