Industrial Filter Bags · Filter Cartridges · Filter Housings · Filter Mesh Manufacturer & Custom Supplier Replacement style · OEM size · Custom micron rating · Industrial filtration supply

What Should Buyers Specify for an INCE-MB-05 5-Bag Filter Housing?

A procurement-focused RFQ checklist for the INCE-MB-05 five-bag filter housing, including reference configuration, process duty, nozzles, materials and GA drawing.

Representative industrial multi bag filter housing

Direct answer: An INCE-MB-05 quotation should state the five-bag arrangement, bag size, material, design duty, inlet/outlet standard, seal, vent/drain/pressure-instrument connections, support basket, opening method and approved general-arrangement drawing. INCE publishes the MB-05 as a five-bag housing with a 550 mm body diameter, DN125 flange connection, 150 T/H reference flow and 3.0 mm reference thickness. These are reference configuration values, not a guaranteed duty point. Start with the multi-bag filter housing product page.

Request an INCE-MB-05 Engineering Quote

Send the liquid, flow range, viscosity, solids, temperature, operating/design pressure, bag size and micron, 304 or 316L preference, nozzle standard/orientation, seal, quantity, destination and any GA drawing requirements.

Send Your Specification

INCE multi-bag filter housing for industrial liquid filtration
Representative INCE multi-bag housing. The approved MB-05 drawing and quotation control the final nozzle layout and dimensions.

What Is the Published INCE-MB-05 Reference Configuration?

Item Published MB-05 reference Procurement note
Bag count 5 bags Confirm support baskets and the exact bag-size code
Body diameter Ø550 mm Reference value; approved drawing controls
Inlet/outlet DN125 flange Specify flange standard, rating, face and orientation
Reference flow 150 T/H Not a guarantee; actual duty depends on liquid, bags, solids and allowable differential pressure
Reference thickness 3.0 mm Final design depends on pressure, temperature, material and applicable design requirements
Material options 304 or 316L published for the multi-bag range Confirm wetted material and corrosion review

The published multi-bag range supports bag sizes #1 through #5 and can be configured with tri-clamp, flange or threaded connections and silicone, FKM, PTFE or EPDM sealing options. Do not assume every combination is available for every pressure, nozzle size or regulatory requirement. The final quotation and approved drawing must list the offered configuration.

Multi-bag filter housing product configuration
Representative multi-bag housing product image. Final materials, bag size, closure and connection details are quotation-specific.

Is the Published 150 T/H a Guaranteed Capacity?

No. It is a published reference flow, not a guaranteed duty point. Actual capacity depends on liquid viscosity and density, solids loading, bag media and micron rating, number of clean bags, allowable clean and terminal differential pressure, pipework and fouling behavior. A comparable RFQ provides the operating range rather than a single pump nameplate value.

  • State the liquid name, concentration, density and viscosity at operating temperature.
  • Provide normal, minimum and maximum flow.
  • Define bag material, nominal or absolute rating, size and expected solids load.
  • State operating, design and upset temperature and pressure separately.
  • Identify whether the process can stop for bag change or requires isolation or bypass planning.
  • List cleaning, drainability, surface-finish or contamination-control requirements.

Which Mechanical Details Must Appear on the RFQ?

Mechanical field Buyer input required
Flange DN/NPS size, standard, pressure class or PN, face type and material
Nozzle orientation Clock position, elevation and preferred inlet/outlet direction
Vent and drain Size, connection type, valve scope and discharge destination
Pressure monitoring Gauge or transmitter ports and differential-pressure arrangement
Closure/access Available headroom, lifting restrictions and service-side clearance
Support/installation Legs or skid interface, anchor details and operating-weight review
Documentation GA drawing, material documents, test records or inspection hold points required by the PO
Single bag filter housing shown for service access comparison
Comparison image only: a single-bag housing is not the MB-05. Use it to discuss footprint and service-access differences before selecting a five-bag unit.

What Should the Approved Drawing Resolve Before Production?

The approved GA drawing should resolve overall height and footprint, nozzle sizes and orientations, vent/drain/instrument ports, closure and lifting arrangement, bag access, support and anchor interface, service clearance and the design basis stated in the quotation. A web image or model name cannot replace this drawing.

RFQ Checklist for a Comparable MB-05 Offer

Category Information to provide
Process Liquid, concentration, viscosity, solids and filtration objective
Duty Normal/maximum flow, pressure, temperature and allowable differential pressure
Filter bags Size, micron rating, media, ring/seal and quantity per change
Materials Wetted body, baskets, seals and any surface-finish requirement
Connections Flange standard/class, orientation, vent, drain and instruments
Commercial Quantity, destination, documentation, inspection and required delivery window

Turn the MB-05 Model Name into a Complete RFQ

Attach a process datasheet and site-layout sketch. INCE can return a quotation basis and GA review list without treating the 150 T/H reference as a universal performance guarantee.

Request a Quote

Frequently Asked Questions

How many filter bags are in the INCE-MB-05?

The published MB-05 reference configuration uses five filter bags. Confirm the bag-size code, basket and sealing arrangement in the quotation.

Is 150 T/H guaranteed for every MB-05 application?

No. It is a published reference flow. Actual capacity depends on the liquid, viscosity, solids, bag media and micron rating, allowable differential pressure and fouling rate.

What should I submit for an MB-05 quotation?

Submit process fluid and duty data, pressure and temperature, bag size and micron, material, flange standard and orientation, seal, vent/drain/instrument needs, quantity, destination and drawing requirements.

Get an MB-05 Quotation

Send the complete duty and connection data. The final offer should identify all assumptions and use the approved drawing as the dimensional control.

Get OEM Pricing

Related Articles

Continue Reading About Liquid Filtration

Need a Filter Bag Recommendation?

Send the liquid, micron target, flow, pressure, temperature, bag dimensions and quantity for review.

Start a Filter Bag Inquiry
Filtration Engineer