Direct answer: An INCE-MB-05 quotation should state the five-bag arrangement, bag size, material, design duty, inlet/outlet standard, seal, vent/drain/pressure-instrument connections, support basket, opening method and approved general-arrangement drawing. INCE publishes the MB-05 as a five-bag housing with a 550 mm body diameter, DN125 flange connection, 150 T/H reference flow and 3.0 mm reference thickness. These are reference configuration values, not a guaranteed duty point. Start with the multi-bag filter housing product page.
Request an INCE-MB-05 Engineering Quote
Send the liquid, flow range, viscosity, solids, temperature, operating/design pressure, bag size and micron, 304 or 316L preference, nozzle standard/orientation, seal, quantity, destination and any GA drawing requirements.

What Is the Published INCE-MB-05 Reference Configuration?
| Item | Published MB-05 reference | Procurement note |
|---|---|---|
| Bag count | 5 bags | Confirm support baskets and the exact bag-size code |
| Body diameter | Ø550 mm | Reference value; approved drawing controls |
| Inlet/outlet | DN125 flange | Specify flange standard, rating, face and orientation |
| Reference flow | 150 T/H | Not a guarantee; actual duty depends on liquid, bags, solids and allowable differential pressure |
| Reference thickness | 3.0 mm | Final design depends on pressure, temperature, material and applicable design requirements |
| Material options | 304 or 316L published for the multi-bag range | Confirm wetted material and corrosion review |
The published multi-bag range supports bag sizes #1 through #5 and can be configured with tri-clamp, flange or threaded connections and silicone, FKM, PTFE or EPDM sealing options. Do not assume every combination is available for every pressure, nozzle size or regulatory requirement. The final quotation and approved drawing must list the offered configuration.

Is the Published 150 T/H a Guaranteed Capacity?
No. It is a published reference flow, not a guaranteed duty point. Actual capacity depends on liquid viscosity and density, solids loading, bag media and micron rating, number of clean bags, allowable clean and terminal differential pressure, pipework and fouling behavior. A comparable RFQ provides the operating range rather than a single pump nameplate value.
- State the liquid name, concentration, density and viscosity at operating temperature.
- Provide normal, minimum and maximum flow.
- Define bag material, nominal or absolute rating, size and expected solids load.
- State operating, design and upset temperature and pressure separately.
- Identify whether the process can stop for bag change or requires isolation or bypass planning.
- List cleaning, drainability, surface-finish or contamination-control requirements.
Which Mechanical Details Must Appear on the RFQ?
| Mechanical field | Buyer input required |
|---|---|
| Flange | DN/NPS size, standard, pressure class or PN, face type and material |
| Nozzle orientation | Clock position, elevation and preferred inlet/outlet direction |
| Vent and drain | Size, connection type, valve scope and discharge destination |
| Pressure monitoring | Gauge or transmitter ports and differential-pressure arrangement |
| Closure/access | Available headroom, lifting restrictions and service-side clearance |
| Support/installation | Legs or skid interface, anchor details and operating-weight review |
| Documentation | GA drawing, material documents, test records or inspection hold points required by the PO |

What Should the Approved Drawing Resolve Before Production?
The approved GA drawing should resolve overall height and footprint, nozzle sizes and orientations, vent/drain/instrument ports, closure and lifting arrangement, bag access, support and anchor interface, service clearance and the design basis stated in the quotation. A web image or model name cannot replace this drawing.
RFQ Checklist for a Comparable MB-05 Offer
| Category | Information to provide |
|---|---|
| Process | Liquid, concentration, viscosity, solids and filtration objective |
| Duty | Normal/maximum flow, pressure, temperature and allowable differential pressure |
| Filter bags | Size, micron rating, media, ring/seal and quantity per change |
| Materials | Wetted body, baskets, seals and any surface-finish requirement |
| Connections | Flange standard/class, orientation, vent, drain and instruments |
| Commercial | Quantity, destination, documentation, inspection and required delivery window |
Turn the MB-05 Model Name into a Complete RFQ
Attach a process datasheet and site-layout sketch. INCE can return a quotation basis and GA review list without treating the 150 T/H reference as a universal performance guarantee.
Frequently Asked Questions
How many filter bags are in the INCE-MB-05?
The published MB-05 reference configuration uses five filter bags. Confirm the bag-size code, basket and sealing arrangement in the quotation.
Is 150 T/H guaranteed for every MB-05 application?
No. It is a published reference flow. Actual capacity depends on the liquid, viscosity, solids, bag media and micron rating, allowable differential pressure and fouling rate.
What should I submit for an MB-05 quotation?
Submit process fluid and duty data, pressure and temperature, bag size and micron, material, flange standard and orientation, seal, vent/drain/instrument needs, quantity, destination and drawing requirements.
Get an MB-05 Quotation
Send the complete duty and connection data. The final offer should identify all assumptions and use the approved drawing as the dimensional control.