Choose an INCE-219 cover by maintenance access, piping layout and the verified pressure design—not by cover shape alone. The flat, concave and turtle-back variants share the same published reference body diameter, nozzle and flow basis; the high-pressure variant has a thicker published shell, but the final allowable duty must still be confirmed from the approved drawing. Review the single bag filter housing product page before issuing a purchase order.
Need a cover-style recommendation? Request an INCE-219 configuration quote. Include the operating liquid, micron or opening target, flow, temperature, pressure, connection, quantity, destination country, and any drawing or incumbent model available.

Which INCE-219 cover should a buyer shortlist?
| Published model | Cover description | Published reference basis | Procurement use |
|---|---|---|---|
| INCE-FC-219 | Flat cover | Ø219 mm; DN50; 20 T/H reference; 3.0 mm shell | Start here when a simple, compact cover is acceptable and access is clear. |
| INCE-CC-219 | Concave cover | Ø219 mm; DN50; 20 T/H reference; 3.0 mm shell | Shortlist when the requested cover geometry or piping envelope calls for a concave profile. |
| INCE-TB-219 | Turtle-back cover | Ø219 mm; DN50; 20 T/H reference; 3.0 mm shell | Use when this closure form suits the plant’s opening and maintenance arrangement. |
| INCE-HV-219 | High-pressure variant | Ø219 mm; DN50; 20 T/H reference; 4.0 mm shell | Request engineering review for elevated duty; 4.0 mm is a published construction reference, not a stand-alone pressure approval. |
| INCE-SC-219 | Single-core variant | Ø219 mm; DN50; 20 T/H reference; 3.0 mm shell | Use when the specified internal single-core arrangement is required. |
The manufacturer lists 304 and 316L stainless steel, a 1.0 MPa design-pressure reference, Size #1 through #5 filter bags, side- or top-entry layouts, clamp/thread/flange connections, and silicone, FKM, PTFE or EPDM sealing options. These are configuration choices, not a blanket statement that every combination is suitable for every chemical, temperature or code requirement.
Why flow and pressure cannot be selected from the model name
The published 20 T/H value is a reference. Actual capacity depends on liquid viscosity and density, clean-bag pressure drop, retained-solids loading, bag media, micron rating, piping losses and the allowable differential pressure. Likewise, the INCE-HV-219 name and 4.0 mm shell reference do not replace a project-specific mechanical calculation or approved data sheet.

What should be fixed on the RFQ?
- Process: liquid name, viscosity, density, solids type/loading, operating and design temperature, normal/maximum flow, inlet pressure and allowable differential pressure.
- Filtration: bag material, nominal or absolute basis if applicable, micron rating, bag size, expected change-out interval and downstream sensitivity.
- Mechanical: 304 or 316L request, cover style, side/top entry, nozzle size and standard, seal material, vent/drain needs, surface finish and support arrangement.
- Compliance: applicable pressure-vessel or plant standard, inspection/document requirements and destination country.
- Commercial: quantity, spare baskets/bags, packaging, requested shipment window and drawing/model of the unit being replaced.
Before INCE confirms the cover Send your operating specification. Include the operating liquid, micron or opening target, flow, temperature, pressure, connection, quantity, destination country, and any drawing or incumbent model available.
Dimensional boundary to keep in the purchase record
The product page shows a Size #2 example around a Ø219 × 3 mm body, with reference overall dimensions that vary by configuration. Treat those figures as orientation only. The signed general-arrangement drawing, nozzle schedule, materials list and design conditions must control production.

A practical purchase decision
For most buyers, the correct sequence is: identify the process duty, choose the bag and seal, confirm the opening and piping envelope, then let INCE match the closure variant. This avoids using the cover label as a substitute for filtration or mechanical design.
Frequently Asked Questions
Does INCE-HV-219 automatically qualify for my system pressure?
No. The published 4.0 mm shell reference helps distinguish the variant, but allowable pressure depends on the complete design, material, temperature, welds, closures, nozzles and applicable standard. Obtain an approved data sheet.
Are the published 20 T/H values guaranteed?
No. They are reference values. Ask for a selection based on viscosity, solids loading, filter bag, pressure drop and piping conditions.
Can the connection and gasket be customized?
The product page lists clamp, threaded and flanged connections plus silicone, FKM, PTFE and EPDM options. Chemical and temperature compatibility must be confirmed for the actual duty.
Ready to compare INCE-FC, CC, TB, HV or SC Get an engineered RFQ review. Include the operating liquid, micron or opening target, flow, temperature, pressure, connection, quantity, destination country, and any drawing or incumbent model available.