Direct answer: to quote an OEM nylon pleated cartridge from a drawing or sample, control the media grade and retention basis, overall and sealing dimensions, OD/ID, end caps, seals, core/cage materials, operating conditions and packaging. A nominal length or competitor model number is not enough to confirm fit.
Send the drawing or clear dimensional photos, original model, micron grade, liquid, temperature, flow, end cap, gasket, sample quantity and annual/batch quantity.
INCE’s nylon NMO pleated cartridge page publishes 0.03–1.2 µm grades, 10–70 inch lengths, several diameters and 215/222/226/threaded/custom end options. Those ranges define available customization—not automatic interchangeability.

Translate the sample into a controlled drawing
Measure the cartridge after identifying whether any seal is compressed, worn or missing. Record overall length, installed/sealing length, body OD, core ID, adapter diameters, end-cap height, fin or bayonet geometry and O-ring-groove dimensions. Photograph both ends beside a scale and show how the element seats in the housing. Where possible, include the housing adapter drawing because a sample alone may not reveal the required compression or flow direction.
| Drawing field | RFQ information |
|---|---|
| Media | Nylon grade, micron/efficiency basis and any support layers |
| Size | Overall length, sealing length, OD, ID and tolerances |
| Ends | DOE/SOE, 215, 222, high 222, 226, threaded, fin, flat or custom geometry |
| Seals | Material, count, cross-section and groove dimensions |
| Structure | Core, outer cage, end-cap material and joining method |
| Marking/packing | Private label, model/lot marks, bagging, carton quantity and export protection |
Select nylon from the complete liquid duty
Nylon can suit compatible neutral aqueous liquids, oils, inks and coatings, but compatibility must be checked against every chemical component, concentration, temperature and cleaning exposure. Provide pH, solvent/oil content and contact time. If a different membrane is required, compare it as a separate validated configuration rather than assuming the same micron label gives the same behavior.

Use the published range carefully
| Micron ratings | 0.03, 0.05, 0.1, 0.2, 0.45, 0.65, 0.8 and 1.2 µm |
|---|---|
| Length | 10–70 inches; selected 20–40 inch lengths may be made in one piece |
| Reference OD | 60, 64, 68, 84 and 131 mm; published OD tolerance ±1 mm |
| Reference ID | 28 mm, with custom options |
| Temperature | Normal operating temperature ≤80°C; published maximum-temperature condition is 80°C at ΔP ≤0.10 MPa |
| Differential pressure | Published reference at 25°C: ΔP ≤0.55 MPa |
Use condition-specific limits: the temperature and differential-pressure references are not interchangeable. The approved configuration and actual operating envelope control. The product page notes a stainless-steel insert option for cartridges intended for hot-water sanitization or steam sterilization; request project confirmation.
Include housing photos or an adapter drawing, flow direction, hold-down method and installed clearance with the cartridge sample.
Approve a sample before bulk production
- Drawing approval: confirm dimensions, tolerances, materials and marking.
- Fit check: install the sample in the intended housing and confirm seal engagement and hold-down.
- Process trial: record clean ΔP, flow, run time and filtrate result with the actual liquid.
- Change control: define which media, end-cap, seal and packaging details may not change without approval.
- Bulk acceptance: agree sample size, dimensional checks, identification and documents.

What to submit for a comparable OEM quotation
- Original model and manufacturer, if available, plus drawing or physical sample.
- Liquid composition, pH, oil/solvent content, temperature, pressure and flow.
- Micron rating and required retention/efficiency evidence.
- Complete cartridge and seal dimensions with tolerances.
- Trial quantity, regular batch quantity and destination country.
- OEM label, individual bag, carton, pallet and document requirements.
FAQ
What dimensions are needed for an OEM nylon pleated cartridge?
Provide overall and sealing length, outside and inside diameter, end-cap dimensions, adapter and fin geometry, seal-groove dimensions, seal count and any housing locating features.
Can a model number alone confirm interchangeability?
Not always. Send the controlled drawing, housing interface or sample because model codes and nominal lengths may hide different sealing and installed dimensions.
Which nylon ratings does INCE publish?
The product page lists 0.03, 0.05, 0.1, 0.2, 0.45, 0.65, 0.8 and 1.2 µm. Confirm the efficiency basis and suitability of the selected grade for the application.
What should be approved before bulk production?
Approve the drawing, materials, micron/efficiency basis, dimensions, end-cap and seal fit, workmanship, trial sample, labels, quantity per carton, protective packing and required inspection records.
Upload the drawing or sample photos and list the liquid, micron grade, dimensions, end cap, seal, quantities and destination for an engineering review.